Wear an ESD grounding strap when handling the chassis.

Always connect a grounding cable to the designated grounding lug on the rear of the chassis before applying power. This is vital for safety and to protect the high-performance ASICs from static discharge.

You are now in the config context. To set an IP on the management port (eth0):

: Ensure clear airflow for the three modular replaceable fans. The system supports both front-to-back and back-to-front airflow options.

| Parameter | Specification | |-----------|----------------| | Operating temp | 0°C to 40°C (32°F to 104°F) | | Humidity | 5% to 85% (non-condensing) | | Airflow | Front-to-back or back-to-front (check fan tray labeling) | | Power (AC) | 100–240 VAC, 50/60 Hz, max 400W | | Power (DC) | –40 VDC to –72 VDC |

SR Linux supports in‑service and standard upgrades using CLI commands. The recommended methods are the command with either an HTTP link or a local binary file.

Detailed technical documentation for the platform is available through the 7250 IXR Hardware Documentation Hub .

To wrap up your deployment, execute the following validation commands to ensure the system is stable:

: Connect required optical cables (e.g., QSFP-DD for 400GE or QSFP28 for 100GE) to the front panel ports. 3. Initial Software Bootstrapping