Then fill the softener with block salt—remember, the Harvey HV3 is designed specifically for block salt, and using granular or tablet salt can block the tray and cause problems with the brine valve. Do not fill the salt compartment higher than the bottom edge of the lift handles on the sides of the softener cabinet, as overfilling can prevent the float valve from operating correctly.
This pipe must run to an outside wall. It is a safety feature in case the unit malfunctions; it ensures excess water exits the building rather than flooding your kitchen. 6. Commissioning the HV3
While there is no specific single public manual exclusively for a " Harvey HV3
: For pre-November 2020 Harvey HV3 models, you can check how much salt is in your salt compartment just by looking through the clear window on the front of the cabinet. As a general guideline, allow one salt block per household member per month, though this can vary based on your water hardness and usage patterns. harvey hv3 water softener installation manual
The maximum working pressure for the HV3 is 8.0 bar, with cold water use only. Ensure your installation complies with all local building regulations and water bylaws.
Perform an annual sanitization cycle using a water softener cleaner fluid to keep the resin bed free of bacterial growth. Troubleshooting Common Issues Probable Cause Corrective Action Water remains hard Bypass valve is open Close the bypass valve completely. Water remains hard Salt level is empty Add block salt and wait 24 hours. Water level too high in cabinet Blocked drain line Check drain hose for kinks or restrictions. Low water pressure Debris in inlet screen
Shut off water, remove inlet hose, and clean the mesh screen. If you want to customize your setup further, let me know: Your (15mm or 22mm?) Then fill the softener with block salt—remember, the
The HV3 requires a drain hose for the regeneration waste water. Connect the drain hose to the barbed elbow located on top of the control valve, which is positioned under the rear top cover of the unit.
: Place the unit near the main internal stopcock and a dedicated waste outlet.
Check that the bypass valve is not still in the 'bypass' position. Ensure the softener is properly connected to the rising main. It is a safety feature in case the
: Monitor all joints while the unit is under pressure. 4. Maintenance BLOCK SALT SOFTENER INSTALLATION INSTRUCTIONS
Connect the stainless steel braided hoses to the respective ports. Ensure the rubber washers are correctly seated inside the hose nuts.